Your self-monitoring system is in order. Temperatures have been measured, recorded, and signed off day after day, and the logbook looks exemplary. Then comes the question that no procedure in the binder answers: how do you know the thermometer was reading correctly? A handheld thermometer dropped on the floor, knocked against a sink, or simply aged a few years can easily be off by a couple of degrees without anything looking amiss on the display. And a log filled with incorrect figures is not merely useless — it is worse than having no log at all, because it looks convincing.
What it is
The KM20REF is a reference thermometer — the instrument you use to check your other thermometers against. It is based on a Pt100 platinum resistance thermometer (PRT) with a permanently attached probe and covers −100 to +199.9 °C. It is supplied with a 5-point UKAS calibration certificate at −18 °C, 0 °C, +8 °C, +20 °C, and +70 °C, features auto-switch off, and comes complete with a carrying case. Combined with a calibration checker (KM820/VAL), it can be used to verify both contact and infrared thermometers.
The problem it solves
Every measurement relies on a chain of trust: the item is measured by an instrument, the instrument is checked against a superior standard, and that standard is in turn calibrated against a national standard. Without that chain, a reading is merely an opinion with decimal places. The reference thermometer is the vital link connecting your day-to-day thermometers to traceability — and that is why it is engineered differently from the instruments it is designed to check.
Pt100 instead of a thermocouple is at the core. A platinum resistor changes predictably and slowly, drifting significantly less over time than a thermocouple, which is also sensitive to cable joins and the temperature at its own connection point. The fact that the probe is permanently attached follows the same principle: the most common source of error in a thermometer with a detachable probe is the instrument-and-probe combination itself, where the probe can be swapped, damaged, or replaced with a different model. Here, the system is calibrated as a single integrated unit, meaning the certificate applies to the exact setup you use.
The five calibration points have been carefully selected, and it is worth noting how well they reflect everyday operations in the food industry: −18 °C represents frozen storage, 0 °C is the ice-point baseline for routine checks, +8 °C sits within the critical chilled storage range, +20 °C is ambient room temperature, and +70 °C falls squarely in the hot-holding zone. In other words, accuracy is certified precisely where critical decisions are made — not just at a convenient point in the middle of the range.
Three typical use cases
- Periodic verification of in-house thermometers: all handheld thermometers and data loggers are compared against the reference at set intervals, with the results documented — providing the evidence needed to stand up to audits.
- Checking infrared (IR) thermometers: used alongside a calibration checker, as non-contact thermometers are otherwise notoriously difficult to verify in the field.
- Investigating deviations: when a reading looks questionable, you need to determine quickly whether it is the process or the instrument that is drifting — without a reference, you are simply guessing.
Why it pays off
Consider the alternative: sending instruments out for external calibration. Each thermometer incurs shipping costs, service fees, and downtime while it is away from the facility — which, in practice, causes calibration intervals to be stretched longer than they should be. Having an in-house reference turns verification into an internal routine that can be carried out at any time, across all instruments, as frequently as your procedures require.
The far greater cost, however, is the one you do not see until something goes wrong. If a thermometer is found to be reading two degrees off, the immediate question is for how long? — and without documented checks, that uncertainty stretches all the way back to its last external calibration. That can leave months of production indefensible. With regular in-house checks against a traceable reference, you know the deviation developed sometime since the last verification, narrowing the window to days rather than months. That is the difference between a manageable deviation and an uncontrolled crisis.
Read more about the KM20REF reference thermometer with 5-point UKAS certificate →