Hoppa till innehåll
Free shipping over 3000 kr excl. VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The cold room was too warm last night, but nobody knew when it startedThe Fuse Trips Once a Night: How to Find the Cause with a Logged Load CurveA core temperature reading in 0.4 seconds makes self-inspection a habit instead of an interruptionWhy Bore Measurements Show Different Values Depending on Who Holds the InstrumentThree Seconds at the Core: How to Make Temperature Control in Food Production Both Faster and SaferThe Brix value decides: get a reading in seconds instead of a guess by eyeThree seconds is enough to tell whether the core temperature holdsTwo-point measurement in an oval hole gives the wrong diameter, three measuring points do notHow to tell in three seconds whether a hole meets the H7 toleranceThe Hole Measures Right in One Direction but Is Still Wrong: Why You Need Three Measuring PointsVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The cold room was too warm last night, but nobody knew when it startedThe Fuse Trips Once a Night: How to Find the Cause with a Logged Load CurveA core temperature reading in 0.4 seconds makes self-inspection a habit instead of an interruptionWhy Bore Measurements Show Different Values Depending on Who Holds the InstrumentThree Seconds at the Core: How to Make Temperature Control in Food Production Both Faster and SaferThe Brix value decides: get a reading in seconds instead of a guess by eyeThree seconds is enough to tell whether the core temperature holdsTwo-point measurement in an oval hole gives the wrong diameter, three measuring points do notHow to tell in three seconds whether a hole meets the H7 toleranceThe Hole Measures Right in One Direction but Is Still Wrong: Why You Need Three Measuring Points

Two-point measurement in an oval hole gives the wrong diameter, three measuring points do not

Published 17 October 2026 at 09:54

Two operators measure the same bore with a two-point gauge and get two different values. The difference is a few hundredths of a millimeter, just enough for a bearing to fit too loosely or a seal to leak. The cause is rarely the instrument. Most often the gauge tilts slightly in the hole, or the hole is not perfectly round, and then the result depends on how the person measuring happens to hold the tool.

Analog internal three-point micrometer of Holtest type for blind holes. Measuring range Ø75–88 mm. Scale division 0.005 mm. Self-centering. Carbide measuring faces. Replaceable measuring pins for larger sizes. Supplied in an aluminum case with an extension.

What a three-point micrometer is

An internal three-point micrometer of the Holtest type has three measuring faces placed 120° apart around the axis. When the measuring head is inserted into the hole and the measuring faces are expanded, the instrument centers itself. This version has a measuring range of Ø75–88 mm, a scale division of 0.005 mm and carbide measuring faces. The measuring pins can be replaced for larger diameters. It is supplied in an aluminum case together with an extension, so that you can reach down into blind holes.

Which problems it solves

Because the instrument centers itself, the biggest error in hole measurement disappears, namely holding the gauge at an angle. Three contact points also give a clear diameter even when the hole is slightly oval or has three lobes, which a two-point gauge can miss entirely depending on which direction it is turned. The carbide faces wear slowly, so the zero point holds for a long time.

When and how it is used

You set the instrument to zero against a setting ring of nominal diameter, insert the measuring head into the hole and turn it until all three measuring faces are in contact. Then you take the reading. Measure at several depths along the hole. That shows whether it has taper, and you can compare the reading at different angles to detect out-of-roundness. It is the setting ring that determines how reliable the zero point is, so it should have a traceable calibration.

Three areas of use

Manufacturing workshops: After honing or fine boring of hydraulic cylinders and valve housings, you check that the holes hold tolerance over their entire length, not just at the mouth.

Maintenance: When overhauling pump housings, compressor cylinders or bearing seats, the measurement shows whether the wear is so great that the part must be replaced or machined. Without a reliable measurement, the decision becomes a guess.

Quality control and metrology labs: For incoming inspection and spot checks, self-centering gives more comparable values between different people and shifts. This reduces discussions about whose measurement is correct.

Why it pays off

The cost of an incorrect hole measurement is seldom the measurement itself. It lies in scrapped parts, rework and complaints that could have been caught at the machine. An instrument that gives the same result no matter who measures saves time at every inspection, since you avoid repeating the measurement just to be sure. The basis for calibration and documentation also becomes easier to stand behind.

If you need to measure bores in the 75–88 mm range with greater confidence than a two-point gauge provides, this micrometer is a natural choice.

Read more

More news

All news