Hoppa till innehåll
Free shipping over 5.227 SEK ex VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The cold room was too warm last night, but nobody knew when it startedThe Fuse Trips Once a Night: How to Find the Cause with a Logged Load CurveA core temperature reading in 0.4 seconds makes self-inspection a habit instead of an interruptionWhy Bore Measurements Show Different Values Depending on Who Holds the InstrumentThree Seconds at the Core: How to Make Temperature Control in Food Production Both Faster and SaferThe Brix value decides: get a reading in seconds instead of a guess by eyeThree seconds is enough to tell whether the core temperature holdsTwo-point measurement in an oval hole gives the wrong diameter, three measuring points do notHow to tell in three seconds whether a hole meets the H7 toleranceThe Hole Measures Right in One Direction but Is Still Wrong: Why You Need Three Measuring PointsVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The cold room was too warm last night, but nobody knew when it startedThe Fuse Trips Once a Night: How to Find the Cause with a Logged Load CurveA core temperature reading in 0.4 seconds makes self-inspection a habit instead of an interruptionWhy Bore Measurements Show Different Values Depending on Who Holds the InstrumentThree Seconds at the Core: How to Make Temperature Control in Food Production Both Faster and SaferThe Brix value decides: get a reading in seconds instead of a guess by eyeThree seconds is enough to tell whether the core temperature holdsTwo-point measurement in an oval hole gives the wrong diameter, three measuring points do notHow to tell in three seconds whether a hole meets the H7 toleranceThe Hole Measures Right in One Direction but Is Still Wrong: Why You Need Three Measuring Points
Item number 56-TR-55I-PT

TandD Compact temperature logger for Pt-100/1000 sensors (sensor not included). Optical data transfer

2.333 SEK

In stock

TandD Compact temperature logger for Pt-100/1000 sensors (sensors not included). Optical data transfer

Request a quote 56-TR-55I-PT

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

  • Free shipping over 3000 kr excl. VAT
  • Thermometers and measuring instruments for work and home
  • Call us +46 8 753 00 04

Category: , , ,

Other models in the series 4

Description

The 56-TR-55I-PT is TandD’s compact logger for Pt sensors — connect Pt100 or Pt1000 in 3- or 4-wire configuration via the included input module, and cover temperatures from -199 to +600 °C with high-precision measurement. Pt sensors offer better accuracy and stability over time compared to thermistors, making it the choice for calibration tasks and industrial precision measurements.

NOTE: Pt sensors are NOT included — ordered separately according to application (rod dimension, cable length, IP class). Optical data transfer via 56-TR-50U2 USB holder (sold separately).

Features

  • 1 channel Pt100 or Pt1000 (3- or 4-wire)
  • Measuring range -199 to +600 °C
  • Resolution 0.1 °C
  • High precision and long-term stability — better than thermistor
  • Temperature adjustment function — compensate for calibration errors
  • 16,000 data point memory (Endless or One Time)
  • 15 fixed logging intervals (1 sec to 60 min)
  • Alarm LED for limit exceedance
  • Built-in LCD
  • Lithium battery approx. 4 years operation
  • Optical communication via 56-TR-50U2

Specification

Measuring channel Temperature 1 channel — Pt100 / Pt1000 (3- or 4-wire)
Measuring range -199 to +600 °C
Resolution 0.1 °C
Logging capacity 16,000 data points
Communication Optical (requires 56-TR-50U2)
Power Supply Lithium battery LS14250
Battery Life approx. 4 years
Dimensions 62 × 47 × 19 mm

Included in the box

  • 56-TR-55I-PT logger with Pt input module
  • 1 × Lithium battery LS14250
  • Manual set with certificate of conformity
  • NOTE: Pt sensor and TR-50U2 holder are NOT included

Applications

The 56-TR-55I-PT is suitable for industrial temperature measurements with high accuracy requirements: calibration tasks, process monitoring in the pharmaceutical industry, climate chambers, heat treatment ovens (low temperature), and cryogenic research. For thermocouples, see 56-TR-55I-TC. For voltage, see 56-TR-55I-V.

Additional information
Product Type

Measures

Temperature

Communication

Optical