Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Measuring from an image is only reliable when the magnification travels with the imageThe freezer lost temperature overnight – with an alert on your phone, you’ll know before the samples are ruinedWith a Steerable Camera Head, You See the Fault Before You Take the Machine ApartA Bore That Is Right at the Opening Can Be Wrong 400 mm Further InWhen the naked eye isn’t enough: measure and document the defect directly in the image instead of guessingMoisture is rarely where you can see it: how to tell whether wood, plasterboard and concrete are dry enoughThe cold room was too warm last night, but nobody knew when it startedThe Fuse Trips Once a Night: How to Find the Cause with a Logged Load CurveA core temperature reading in 0.4 seconds makes self-inspection a habit instead of an interruptionWhy Bore Measurements Show Different Values Depending on Who Holds the InstrumentVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Measuring from an image is only reliable when the magnification travels with the imageThe freezer lost temperature overnight – with an alert on your phone, you’ll know before the samples are ruinedWith a Steerable Camera Head, You See the Fault Before You Take the Machine ApartA Bore That Is Right at the Opening Can Be Wrong 400 mm Further InWhen the naked eye isn’t enough: measure and document the defect directly in the image instead of guessingMoisture is rarely where you can see it: how to tell whether wood, plasterboard and concrete are dry enoughThe cold room was too warm last night, but nobody knew when it startedThe Fuse Trips Once a Night: How to Find the Cause with a Logged Load CurveA core temperature reading in 0.4 seconds makes self-inspection a habit instead of an interruptionWhy Bore Measurements Show Different Values Depending on Who Holds the Instrument
Item number 17-813526

ETI TDS2 ppm conductivity meter. Measures ppm (parts per million). Resolution 100ppm, range 100-9999

1.224 SEK

In stock

TDS Conductivity Tester

  • Genuinely pocket-sized
  • Easy-to-read 6 mm LCD display
  • Indicates ppm (parts per million) or µS (micro-siemens)
  • Accuracy of ±2% of full scale
Documents:813 525 C of C
Request a quote 17-813526

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

  • Free shipping over 3000 kr excl. VAT
  • Thermometers and measuring instruments for work and home
  • Call us +46 8 753 00 04

Category:

Description

These TDS conductivity meters provide the perfect solution for measuring ppm or μS. The TDS meters are ideal for monitoring a wide range of applications, including the amount of salts or dissolved solids in water. Readings are automatically temperature compensated within the range of 0 to 50 °C.

There are two models of both TDS and conductivity meters, suitable for either low or high concentrations of total dissolved solids in liquids.

Conductivity Electrode Maintenance

The ETI range of conductivity meters includes TDS meters, nutrient meters, salt concentration meters, and WalkLAB Pro conductivity meters.

Various calibration solutions are available for regular calibration of the instruments.

Storage: It is best to store cells with the electrodes immersed in deionized water. All cells that have been stored dry should be soaked in distilled water for 5 to 10 minutes before use to ensure complete wetting of the electrodes.

The single most important requirement for accurate and reproducible results in conductivity measurement is a clean cell. A dirty cell will contaminate the solution and cause the conductivity to change. Grease, oil, fingerprints, and other contaminants on the sensing elements can cause inaccurate measurements and sporadic reactions.

Electrodes can be cleaned with a mixture of 1 volume part isopropyl alcohol, 1 part ethyl ether, and 1 part HCl (1+1). After cleaning, rinse the cell thoroughly with water. If the old platinum black coating needs to be removed, it is often successful to apply aqua regia to the electrodes, or perform electrolysis in HCl. This should only be attempted by trained operators.

Electrodes can also be cleaned with detergents and/or nitric acid (1%) by dipping or filling the cell with the cleaning solution and stirring for two or three minutes.


Rinse the cell several times with distilled or deionized water and measure the cell constant before use.

Range: TDS1: 10-1990, TDS2: 100-9999, COND3: 10-1990, COND4: 100-19900
Resolution: TDS1: 10 ppm, TDS2: 100 ppm, COND3: 10µS, COND4: 100µS
Accuracy: ±2% of full scale
Battery: 4 x 1.5 volt LR44 button cell
Battery life: 100 hours
Display: 6 mm LCD
Dimensions: 15 x 32 x 147 mm
Weight: 70 grams
Packaging material: ABS plastic
Warranty: one year
Water/dust resistance: waterproof
Measurement scale: ppm (TDS1 & TDS2) or µS (COND3 & COND4)