Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%When the naked eye isn’t enough: measure and document the defect directly in the image instead of guessingMoisture is rarely where you can see it: how to tell whether wood, plasterboard and concrete are dry enoughThe cold room was too warm last night, but nobody knew when it startedThe Fuse Trips Once a Night: How to Find the Cause with a Logged Load CurveA core temperature reading in 0.4 seconds makes self-inspection a habit instead of an interruptionWhy Bore Measurements Show Different Values Depending on Who Holds the InstrumentThree Seconds at the Core: How to Make Temperature Control in Food Production Both Faster and SaferThe Brix value decides: get a reading in seconds instead of a guess by eyeThree seconds is enough to tell whether the core temperature holdsTwo-point measurement in an oval hole gives the wrong diameter, three measuring points do notVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%When the naked eye isn’t enough: measure and document the defect directly in the image instead of guessingMoisture is rarely where you can see it: how to tell whether wood, plasterboard and concrete are dry enoughThe cold room was too warm last night, but nobody knew when it startedThe Fuse Trips Once a Night: How to Find the Cause with a Logged Load CurveA core temperature reading in 0.4 seconds makes self-inspection a habit instead of an interruptionWhy Bore Measurements Show Different Values Depending on Who Holds the InstrumentThree Seconds at the Core: How to Make Temperature Control in Food Production Both Faster and SaferThe Brix value decides: get a reading in seconds instead of a guess by eyeThree seconds is enough to tell whether the core temperature holdsTwo-point measurement in an oval hole gives the wrong diameter, three measuring points do not
Item number 17-813771

ETI HortiCare salinity meter (EC). Measures mS, cF and TDS

1.639 SEK

In stock

HortiCare nutrient tester

Automatic recalibration facility
Measures EC (mS), cF or TDS (ppm) levels
Accurately checks nutrient solutions
Water-resistant case

Request a quote 17-813771

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

  • Free shipping over 3000 kr excl. VAT
  • Thermometers and measuring instruments for work and home
  • Call us +46 8 753 00 04

Category: , ,

Other models in the series 16

Description

The HortiCare nutrient tester is designed to test nutrient levels in solutions feeding plant roots. The unit will test the levels of other essential mineral substances in soluble form. This easy-to-use instrument is housed in a waterproof case, suitable for everyday use, and features an easy-to-read 8 mm LCD display. The unit measures EC (mS), cF, or TDS (ppm) at the touch of a button. The HortiCare nutrient tester includes an automatic calibration function. At the touch of a button, the instrument automatically recalibrates itself when used in conjunction with a 2.8 mS (67 cF or 4700 ppm) standard solution. The HortiCare tester is ideal for testing the amount of dissolved solids (nutrients) in water.
 
Conductivity Electrode Maintenance
The ETI range of conductivity meters includes TDS testers and nutrient testers.
Various calibration solutions are available for regular instrument calibration
Storage: It is best to store cells so that the electrodes are immersed in deionised water. Any cell that has been stored dry should be soaked in distilled water for 5 to 10 minutes prior to use to ensure complete wetting of the electrodes.
The single most important requirement for accurate and reproducible results in conductivity measurement is a clean cell. A dirty cell will contaminate the solution and cause conductivity to change. Grease, oil, fingerprints, and other contaminants on the sensing elements can cause inaccurate measurements and erratic responses.
Electrodes can be cleaned with a mixture of 1 part by volume of isopropyl alcohol, 1 part ethyl ether, and 1 part HCl (1+1). After cleaning, thoroughly flush the cell with water. If the old platinum black coating is to be removed, applying aqua regia to the electrodes or electrolysis in HCl is often successful. This should only be attempted by trained operators.
Electrodes can also be cleaned with detergent and/or nitric acid (1%) by immersing or filling the cell with cleaning solution and agitating for two or three minutes. Rinse the cell several times with distilled or deionised water and remeasure the cell constant before use.
 

Specifications

Mätområde: EC: 0 to 10.0 mS, cF: 0 to 100 cF, TDS: 0 to 7000 ppm
Upplösning: EC: 0.1 mS, cF: 1 cF, TDS: 100 ppm
Noggrannhet: EC: ± 0.2mS, cF: ± 2 cF, TDS: ±2% of full scale
Battery: 4 x 1.5 V LR44 button cell
Battery life: 100 hours
Display: 8 mm LCD
Dimensions: 15 x 32 x 170 mm
Weight: 70 g
Housing material: ABS plastic
Warranty: One year
Water/dust resistance: Water resistant
Measurement scale: EC, cF, and TDS