Hoppa till innehåll
Free shipping over 5.552 SEK ex VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The cold room was too warm last night, but nobody knew when it startedThe Fuse Trips Once a Night: How to Find the Cause with a Logged Load CurveA core temperature reading in 0.4 seconds makes self-inspection a habit instead of an interruptionWhy Bore Measurements Show Different Values Depending on Who Holds the InstrumentThree Seconds at the Core: How to Make Temperature Control in Food Production Both Faster and SaferThe Brix value decides: get a reading in seconds instead of a guess by eyeThree seconds is enough to tell whether the core temperature holdsTwo-point measurement in an oval hole gives the wrong diameter, three measuring points do notHow to tell in three seconds whether a hole meets the H7 toleranceThe Hole Measures Right in One Direction but Is Still Wrong: Why You Need Three Measuring PointsVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The cold room was too warm last night, but nobody knew when it startedThe Fuse Trips Once a Night: How to Find the Cause with a Logged Load CurveA core temperature reading in 0.4 seconds makes self-inspection a habit instead of an interruptionWhy Bore Measurements Show Different Values Depending on Who Holds the InstrumentThree Seconds at the Core: How to Make Temperature Control in Food Production Both Faster and SaferThe Brix value decides: get a reading in seconds instead of a guess by eyeThree seconds is enough to tell whether the core temperature holdsTwo-point measurement in an oval hole gives the wrong diameter, three measuring points do notHow to tell in three seconds whether a hole meets the H7 toleranceThe Hole Measures Right in One Direction but Is Still Wrong: Why You Need Three Measuring Points
Item number 10-SRH77A

Temperature / Humidity Thermistor Instrument

Call for price

In stock

The SRH77A features include a backlight display for dark environments, a sealed keypad which protects the instrument from spills and dust, and a battery eliminator jack. 3-Zone. Min/Max memory. The auto shut-off begins after 15 minutes of non-use or continuous ON mode. It features temperature differential between zones 1 and 2, %RH and wet bulb.

Constant monitoring of min/max temperature from three probes allows technicians to monitor critical temperatures remotely while performing other tasks.

The SILRENGÖRINGSMODUL77A includes: Model 1075 general purpose piercing probe, Model 4011 hose clamp probe, and Model 5028 humidity sensor.

Request a quote 10-SRH77A
  • Free shipping over 3000 kr excl. VAT
  • Thermometers and measuring instruments for work and home
  • Call us +46 8 753 00 04

Category:

Description
Backlight Backlight
Certifications CE, RoHS, NIST, WEEE
Temperature difference Temperature difference between zones 1 & 2
Case Robust hard carrying case
Automatic shutdown After 15 minutes of inactivity or continuous ON mode
Humidity 10 to 95% RH, 90% non-condensing
RH % RH and Wet Bulb
Zones 3 Zones
Switchable °F/ °C Yes
Memory Min/Max memory
Warranty 5-year warranty on the instrument, 1 year on probe
Calibration Factory calibrated
Keypad Sealed keypad protects the instrument from spills & dust
Temperature range -40 °F 300 °F ( -40 to 150 °C)
Temperature Accuracy ±0.3°F or ±0.5% Reading, whichever is greater Resolution 0.1°, 1% RH Weight 1LB 5oz (595g) Dimensions 9,5 × 6,5 × 3,5 ” (241 mm x 165 mm x 89 mm) Battery Type (1) 9v alkaline Battery Life 90 Hours
Specification
Backlight Backlight
Certifications CE, RoHS, NIST, WEEE
Temperature difference Temperature difference between zones 1 & 2
Case Robust hard carrying case
Automatic shutdown After 15 minutes of inactivity or continuous ON mode
Humidity 10 to 95% RH, 90% non-condensing
RH % RH and Wet Bulb
Zones 3 Zones
Switchable °F/ °C Yes
Memory Min/Max memory
Warranty 5-year warranty on the instrument, 1 year on probe
Calibration Factory calibrated
Keypad Sealed keypad protects the instrument from spills & dust
Temperature range -40 °F 300 °F ( -40 to 150 °C)
Temperature Accuracy ±0.3°F or ±0.5% Reading, whichever is greater Resolution 0.1°, 1% RH Weight 1LB 5oz (595g) Dimensions 9,5 × 6,5 × 3,5 ” (241 mm x 165 mm x 89 mm) Battery Type (1) 9v alkaline Battery Life 90 Hours
PDF (2)
Reviews (0)

There are no reviews yet.

Be the first to review

Your e-mail address is not published.

Your rating *