Hoppa till innehåll
Free shipping over 3000 kr excl. VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The cold room was too warm last night, but nobody knew when it startedThe Fuse Trips Once a Night: How to Find the Cause with a Logged Load CurveA core temperature reading in 0.4 seconds makes self-inspection a habit instead of an interruptionWhy Bore Measurements Show Different Values Depending on Who Holds the InstrumentThree Seconds at the Core: How to Make Temperature Control in Food Production Both Faster and SaferThe Brix value decides: get a reading in seconds instead of a guess by eyeThree seconds is enough to tell whether the core temperature holdsTwo-point measurement in an oval hole gives the wrong diameter, three measuring points do notHow to tell in three seconds whether a hole meets the H7 toleranceThe Hole Measures Right in One Direction but Is Still Wrong: Why You Need Three Measuring PointsVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The cold room was too warm last night, but nobody knew when it startedThe Fuse Trips Once a Night: How to Find the Cause with a Logged Load CurveA core temperature reading in 0.4 seconds makes self-inspection a habit instead of an interruptionWhy Bore Measurements Show Different Values Depending on Who Holds the InstrumentThree Seconds at the Core: How to Make Temperature Control in Food Production Both Faster and SaferThe Brix value decides: get a reading in seconds instead of a guess by eyeThree seconds is enough to tell whether the core temperature holdsTwo-point measurement in an oval hole gives the wrong diameter, three measuring points do notHow to tell in three seconds whether a hole meets the H7 toleranceThe Hole Measures Right in One Direction but Is Still Wrong: Why You Need Three Measuring Points
Item number 52-BKPR-2

Palm Abbe Digital Honey Refractometer

5.737 SEK

In stock

User-friendly instrument with exceptional precision for measuring moisture and dry matter in honey.

Request a quote 52-BKPR-2

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

  • Free shipping over 3000 kr excl. VAT
  • Thermometers and measuring instruments for work and home
  • Call us +46 8 753 00 04

Category: ,

Description

Although this instrument is specifically designed for inspectors responsible for measuring and classifying honey, Misco’s digital honey refractometer, the BKPR-2, is equally useful for professional beekeepers and honey producers. -Or anyone who requires the most accurate, repeatable measurements of moisture content and percentage of solids in honey.

The Palm Abbe honey refractometer BKPR-2 delivers the highest quality level in honey measurement. It far exceeds the requirements for honey refractometers used in the classification and control of honey by the USFDA, the Canadian Food Inspection Agency, and food and agricultural organizations within the UN.

Simply place one or two drops of honey into the stainless steel measuring bowl, close the lid to prevent moisture absorption, and then press the measure button to obtain a quick, accurate reading of moisture content or dissolved dry solids.

The magic behind the precision of the BKPR-2 is the result of Palm Abbe’s optical engine. This optical engine combines high-precision optics with a linear detector matrix containing 1024 elements, more than seven times that of competitors. The detector matrix gives the BKPR-2 a repeatability better than +/-0.1% moisture or dry solids!

Since honey consists of a mixture of mostly fructose, glucose, and water, the sample response from the BKPR-2 is automatically temperature-compensated for honey. This differs from other refractometers that use ”sucrose” temperature compensation instead of honey equivalent. Refractometers using sucrose equivalent will have a measurement error already at 25 °C, which increases with temperature. Instruments without temperature compensation can yield measurement errors of more than 3%.

The BKPR-2 features a precisely machined stainless steel measuring bowl that prevents further water absorption. The prism at the bottom of the measuring bowl is made of sapphire, the second hardest material known after diamond. The result is a surface that is virtually impossible to scratch.

The user interface of the honey refractometer consists of only two buttons that are both intuitive and easy to learn. A large two-line, 24-character LCD display provides the user with an indication of the measurement unit (percent moisture or percent dissolved solids) and the actual measured value. Text messages, various menu options, and any error messages are also displayed.

Although the BKPR-2 can be calibrated with water, a calibration solution is also available for purchase that is suitable for the BKPR-2 at 18.6% moisture, giving you the opportunity for the most accurate calibration in this critical area of the scale.

Specification

Although this instrument is specifically designed for inspectors responsible for measuring and classifying honey, Misco’s digital honey refractometer, the BKPR-2, is equally useful for professional beekeepers and honey producers. -Or anyone who requires the most accurate, repeatable measurements of moisture content and percentage of solids in honey.

The Palm Abbe honey refractometer BKPR-2 delivers the highest quality level in honey measurement. It far exceeds the requirements for honey refractometers used in the classification and control of honey by the USFDA, the Canadian Food Inspection Agency, and food and agricultural organizations within the UN.

Simply place one or two drops of honey into the stainless steel measuring bowl, close the lid to prevent moisture absorption, and then press the measure button to obtain a quick, accurate reading of moisture content or dissolved dry solids.

The magic behind the precision of the BKPR-2 is the result of Palm Abbe’s optical engine. This optical engine combines high-precision optics with a linear detector matrix containing 1024 elements, more than seven times that of competitors. The detector matrix gives the BKPR-2 a repeatability better than +/-0.1% moisture or dry solids!

Since honey consists of a mixture of mostly fructose, glucose, and water, the sample response from the BKPR-2 is automatically temperature-compensated for honey. This differs from other refractometers that use ”sucrose” temperature compensation instead of honey equivalent. Refractometers using sucrose equivalent will have a measurement error already at 25 °C, which increases with temperature. Instruments without temperature compensation can yield measurement errors of more than 3%.

The BKPR-2 features a precisely machined stainless steel measuring bowl that prevents further water absorption. The prism at the bottom of the measuring bowl is made of sapphire, the second hardest material known after diamond. The result is a surface that is virtually impossible to scratch.

The user interface of the honey refractometer consists of only two buttons that are both intuitive and easy to learn. A large two-line, 24-character LCD display provides the user with an indication of the measurement unit (percent moisture or percent dissolved solids) and the actual measured value. Text messages, various menu options, and any error messages are also displayed.

Although the BKPR-2 can be calibrated with water, a calibration solution is also available for purchase that is suitable for the BKPR-2 at 18.6% moisture, giving you the opportunity for the most accurate calibration in this critical area of the scale.