Hoppa till innehåll
Free shipping over 3000 kr excl. VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%A Bore That Is Right at the Opening Can Be Wrong 400 mm Further InWhen the naked eye isn’t enough: measure and document the defect directly in the image instead of guessingMoisture is rarely where you can see it: how to tell whether wood, plasterboard and concrete are dry enoughThe cold room was too warm last night, but nobody knew when it startedThe Fuse Trips Once a Night: How to Find the Cause with a Logged Load CurveA core temperature reading in 0.4 seconds makes self-inspection a habit instead of an interruptionWhy Bore Measurements Show Different Values Depending on Who Holds the InstrumentThree Seconds at the Core: How to Make Temperature Control in Food Production Both Faster and SaferThe Brix value decides: get a reading in seconds instead of a guess by eyeThree seconds is enough to tell whether the core temperature holdsVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%A Bore That Is Right at the Opening Can Be Wrong 400 mm Further InWhen the naked eye isn’t enough: measure and document the defect directly in the image instead of guessingMoisture is rarely where you can see it: how to tell whether wood, plasterboard and concrete are dry enoughThe cold room was too warm last night, but nobody knew when it startedThe Fuse Trips Once a Night: How to Find the Cause with a Logged Load CurveA core temperature reading in 0.4 seconds makes self-inspection a habit instead of an interruptionWhy Bore Measurements Show Different Values Depending on Who Holds the InstrumentThree Seconds at the Core: How to Make Temperature Control in Food Production Both Faster and SaferThe Brix value decides: get a reading in seconds instead of a guess by eyeThree seconds is enough to tell whether the core temperature holds
Item number 56-TR-73U

TandD Handheld Logger for Temperature, Humidity and Atmospheric Pressure (3 Channels). LCD Display, USB

3.835 SEK

In stock

TandD Handheld logger for temperature, humidity, and atmospheric pressure (3 channels). LCD display, USB

Request a quote 56-TR-73U

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

  • Free shipping over 3000 kr excl. VAT
  • Thermometers and measuring instruments for work and home
  • Call us +46 8 753 00 04

Category: , , , , , ,

Other models in the series 6

Description

The 56-TR-73U is TandD’s 3-channel handheld logger that measures temperature, humidity AND atmospheric pressure simultaneously in a single unit — perfect for weather documentation, calibration measurements, and quality control where all three parameters are required at the same time.

The included TR-3100 T/RH probe provides 0–55 °C / 10–95 %RH with ±0,3 °C accuracy in the calibration range of 0–50 °C. The built-in barometer measures 750–1100 hPa with ±1,5 hPa accuracy. The logger is approved according to RTCA DO-160E Section 21 for radio frequency emission — meaning it can be carried on board flights as carry-on luggage and used during flight without interfering with avionics. Highly useful for air freight documentation of temperature-sensitive cargo.

Features

  • 3 channels: temperature, humidity and atmospheric pressure
  • Temp/RH with external TR-3100 probe: 0 to +55 °C / 10 to 95 %RH
  • Atmospheric pressure (internal sensor): 750 to 1100 hPa
  • Accuracy T: ±0,3 °C (0–50 °C) / ±0,5 °C / ±1,5 hPa
  • Resolution 0,1 °C / 1 %RH / 0,1 hPa
  • Direct USB 2.0 Mini-B connection to PC
  • 8,000 data point memory (combined for all 3 channels)
  • 15 fixed logging intervals: 1–60 sec or 1–60 min
  • RTCA DO-160E Section 21 approved — can be used in the aircraft cabin
  • Powered by 1 × AA battery for approx. 10 months
  • Front buttons for start/stop, interval selection, display selection
  • Built-in LCD with rotation of all values
  • Specification

    Measuring channels Temperature 1 channel (external TR-3100) + Humidity 1 channel (external) + Atmospheric pressure 1 channel (internal)
    Measuring range T (included probe) 0 to +55 °C, optional: -40 to +110 °C
    Measuring range RH 10 to 95 %RH
    Measuring range pressure 750 to 1100 hPa
    Accuracy ±0.3 °C (0–50 °C, calibration) / ±5 %RH / ±1.5 hPa
    Resolution 0.1 °C / 1 %RH / 0.1 hPa
    Response time (90 %) T/RH: approx. 7 min; Pressure: 4 sec (1 sec interval) or 40 sec (≥10 sec interval)
    Logging capacity 8,000 data points
    Communication USB 2.0 Mini-B, serial (via optional cable 56-TR-07C)
    Power supply 1 × AA alkaline LR6 (included)
    Battery life approx. 10 months
    Dimensions 55 × 78 × 18 mm
    Weight approx. 40 g
    Operating environment -10 to +60 °C, max 90 % RH non-condensing
    Certificates RTCA DO-160E Section 21 (airborne radio emission)

    Included

    • 56-TR-73U logger
    • 1 × AA alkaline battery
    • External T/RH probe 56-TR-3100
    • USB Mini-B cable 56-US-15C
    • Manual set with warranty certificate

    Applications

    The 56-TR-73U is selected for applications where atmospheric pressure is critical: air transport of temperature-sensitive products (pharmaceuticals, biochemical samples, sensitive electronic components), weather documentation, calibration tasks requiring pressure-compensated T/RH values, high-altitude measurements, dive centers, and vehicle testing centers. For simpler T/RH without pressure, see 56-TR-72NW (Ethernet) or 56-TR72A2 (WiFi).

    Additional information
    Product Type

    Measures

    % Relative Humidity, Air Pressure, Temperature

    Communication

    Wired USB

    Specification

    The 56-TR-73U is TandD’s 3-channel handheld logger that measures temperature, humidity AND atmospheric pressure simultaneously in a single unit — perfect for weather documentation, calibration measurements, and quality control where all three parameters are required at the same time.

    The included TR-3100 T/RH probe provides 0–55 °C / 10–95 %RH with ±0,3 °C accuracy in the calibration range of 0–50 °C. The built-in barometer measures 750–1100 hPa with ±1,5 hPa accuracy. The logger is approved according to RTCA DO-160E Section 21 for radio frequency emission — meaning it can be carried on board flights as carry-on luggage and used during flight without interfering with avionics. Highly useful for air freight documentation of temperature-sensitive cargo.

    Features

    • 3 channels: temperature, humidity and atmospheric pressure
    • Temp/RH with external TR-3100 probe: 0 to +55 °C / 10 to 95 %RH
    • Atmospheric pressure (internal sensor): 750 to 1100 hPa
    • Accuracy T: ±0,3 °C (0–50 °C) / ±0,5 °C / ±1,5 hPa
    • Resolution 0,1 °C / 1 %RH / 0,1 hPa
    • Direct USB 2.0 Mini-B connection to PC
    • 8,000 data point memory (combined for all 3 channels)
    • 15 fixed logging intervals: 1–60 sec or 1–60 min
    • RTCA DO-160E Section 21 approved — can be used in the aircraft cabin
    • Powered by 1 × AA battery for approx. 10 months
    • Front buttons for start/stop, interval selection, display selection
  • Built-in LCD with rotation of all values
  • Specification

    Measuring channels Temperature 1 channel (external TR-3100) + Humidity 1 channel (external) + Atmospheric pressure 1 channel (internal)
    Measuring range T (included probe) 0 to +55 °C, optional: -40 to +110 °C
    Measuring range RH 10 to 95 %RH
    Measuring range pressure 750 to 1100 hPa
    Accuracy ±0.3 °C (0–50 °C, calibration) / ±5 %RH / ±1.5 hPa
    Resolution 0.1 °C / 1 %RH / 0.1 hPa
    Response time (90 %) T/RH: approx. 7 min; Pressure: 4 sec (1 sec interval) or 40 sec (≥10 sec interval)
    Logging capacity 8,000 data points
    Communication USB 2.0 Mini-B, serial (via optional cable 56-TR-07C)
    Power supply 1 × AA alkaline LR6 (included)
    Battery life approx. 10 months
    Dimensions 55 × 78 × 18 mm
    Weight approx. 40 g
    Operating environment -10 to +60 °C, max 90 % RH non-condensing
    Certificates RTCA DO-160E Section 21 (airborne radio emission)

    Included

    • 56-TR-73U logger
    • 1 × AA alkaline battery
    • External T/RH probe 56-TR-3100
    • USB Mini-B cable 56-US-15C
    • Manual set with warranty certificate

    Applications

    The 56-TR-73U is selected for applications where atmospheric pressure is critical: air transport of temperature-sensitive products (pharmaceuticals, biochemical samples, sensitive electronic components), weather documentation, calibration tasks requiring pressure-compensated T/RH values, high-altitude measurements, dive centers, and vehicle testing centers. For simpler T/RH without pressure, see 56-TR-72NW (Ethernet) or 56-TR72A2 (WiFi).

    PDF (1)