Hoppa till innehåll
Free shipping over 3000 kr excl. VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%A core temperature reading in 0.4 seconds makes self-inspection a habit instead of an interruptionWhy Bore Measurements Show Different Values Depending on Who Holds the InstrumentThree Seconds at the Core: How to Make Temperature Control in Food Production Both Faster and SaferThe Brix value decides: get a reading in seconds instead of a guess by eyeThree seconds is enough to tell whether the core temperature holdsTwo-point measurement in an oval hole gives the wrong diameter, three measuring points do notHow to tell in three seconds whether a hole meets the H7 toleranceThe Hole Measures Right in One Direction but Is Still Wrong: Why You Need Three Measuring PointsWhy the Multimeter Shows the Wrong Voltage on a Variable Frequency Drive and How True RMS Fixes ItMotion blur hides the defect: how strobe lighting freezes a fast-moving detail in the microscope imageVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%A core temperature reading in 0.4 seconds makes self-inspection a habit instead of an interruptionWhy Bore Measurements Show Different Values Depending on Who Holds the InstrumentThree Seconds at the Core: How to Make Temperature Control in Food Production Both Faster and SaferThe Brix value decides: get a reading in seconds instead of a guess by eyeThree seconds is enough to tell whether the core temperature holdsTwo-point measurement in an oval hole gives the wrong diameter, three measuring points do notHow to tell in three seconds whether a hole meets the H7 toleranceThe Hole Measures Right in One Direction but Is Still Wrong: Why You Need Three Measuring PointsWhy the Multimeter Shows the Wrong Voltage on a Variable Frequency Drive and How True RMS Fixes ItMotion blur hides the defect: how strobe lighting freezes a fast-moving detail in the microscope image
Item number 56-TR-55I-P

TandD Compact logger for pulse counting, excl. sensor. Optical data transfer

1.759 SEK

In stock

TandD Compact logger for pulse counting, excl. sensor. Optical data transmission

Request a quote 56-TR-55I-P

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

  • Free shipping over 3000 kr excl. VAT
  • Thermometers and measuring instruments for work and home
  • Call us +46 8 753 00 04

Category: , , ,

Other models in the series 16

Description

The 56-TR-55I-P is TandD’s compact pulse counter logger — it counts pulse signals (0 to 61,439 counts) from flow meters, electricity meters, tachometers, dosing systems, and other probes/sensors with digital pulse output. It supports both contact input (potential-free) and voltage input. Built-in scale conversion allows you to display l/min, kWh, revolutions, or dose units directly.

Optical data transfer via the 56-TR-50U2 USB holder. 4-year battery life on a single lithium cell.

Features

  • 1-channel pulse counting (0 to 61,439 counts)
  • Contact input or voltage input
  • Scale conversion — display flow, energy, or revolutions directly
  • 16,000 data points
  • 15 fixed logging intervals
  • Alarm LED
  • 4-year battery life
  • Optical communication via 56-TR-50U2

Specification

Measurement Channel 1-channel pulse counting — 0 to 61,439 counts
Input Signal Contact input or voltage input
Logging Capacity 16,000 data points
Special Function Scale conversion
Communication Optical (requires 56-TR-50U2)
Power Supply Lithium battery LS14250
Battery Life Approx. 4 years
Dimensions 62 × 47 × 19 mm

In the Box

  • 56-TR-55I-P logger with pulse counting module
  • 1 × Lithium battery LS14250
  • Manual set with warranty certificate

Applications

The 56-TR-55I-P is suitable for energy and flow monitoring: electricity meters with pulse output, water flow meters, gas flow meters, machine tachometry, and dosing systems. For voltage signals, see the 56-TR-55I-V. For 4-20 mA, see the 56-TR-55I-MA.

Additional information
Product Type

Measures

Pulse Counting

Communication

Optical

PDF (1)