Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%With a Steerable Camera Head, You See the Fault Before You Take the Machine ApartA Bore That Is Right at the Opening Can Be Wrong 400 mm Further InWhen the naked eye isn’t enough: measure and document the defect directly in the image instead of guessingMoisture is rarely where you can see it: how to tell whether wood, plasterboard and concrete are dry enoughThe cold room was too warm last night, but nobody knew when it startedThe Fuse Trips Once a Night: How to Find the Cause with a Logged Load CurveA core temperature reading in 0.4 seconds makes self-inspection a habit instead of an interruptionWhy Bore Measurements Show Different Values Depending on Who Holds the InstrumentThree Seconds at the Core: How to Make Temperature Control in Food Production Both Faster and SaferThe Brix value decides: get a reading in seconds instead of a guess by eyeVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%With a Steerable Camera Head, You See the Fault Before You Take the Machine ApartA Bore That Is Right at the Opening Can Be Wrong 400 mm Further InWhen the naked eye isn’t enough: measure and document the defect directly in the image instead of guessingMoisture is rarely where you can see it: how to tell whether wood, plasterboard and concrete are dry enoughThe cold room was too warm last night, but nobody knew when it startedThe Fuse Trips Once a Night: How to Find the Cause with a Logged Load CurveA core temperature reading in 0.4 seconds makes self-inspection a habit instead of an interruptionWhy Bore Measurements Show Different Values Depending on Who Holds the InstrumentThree Seconds at the Core: How to Make Temperature Control in Food Production Both Faster and SaferThe Brix value decides: get a reading in seconds instead of a guess by eye

Measure on the flanks instead of the crest, and it doesn’t matter if the crest is correct

Published 25 August 2026 at 11:51

Every measurement has a reference, and the reference is always the weakest link. If you measure tooth thickness by first setting a depth from the tooth tip, the tip height is factored into the result — and the tip is the surface of a gear tooth that has the least to do with its function. It is often roughly machined, prone to wear, and the first part to suffer damage during handling.

The flanks, on the other hand, do the actual work. That is where teeth mesh, where power is transmitted, and where wear really matters. So why not measure there?

Digital mikrometer med maetstaed foer maetning paa kuggar, 75-100 mm

What it is

A digital micrometer with specialized measuring faces for gear tooth measurement.

  • Measuring range 75 to 100 mm, accuracy ±0.007 mm, resolution 0.001 mm
  • Radius-shaped anvil R10 mm, spindle Ø8 mm
  • Non-rotating spindle
  • Absolute encoder — zero reference is maintained through battery replacement
  • mm/inch, ABS/INC, reset and preset, automatic shut-off
  • Ratchet stop for constant measuring force, heat-insulated frame

Why the anvil profile is key

A rounded measuring face makes point contact with the flank. A flat measuring face requires a flat surface to rest against, and no such surface exists on a gear tooth — it is curved all the way. A radius shape, however, always finds a single contact point on the flank regardless of the tooth angle, right where the load is actually carried.

This means the tooth tip is no longer part of the measurement. Variations in tip height or minor deviations in outside diameter do not affect the result, as the instrument never touches the tip. The reference point has been shifted to the surface that counts.

The non-rotating spindle is not a luxury here — it is essential. On a standard micrometer, the measuring face rotates as you screw it in. Against a flat surface, that is not an issue. Against a curved flank, however, the contact point shifts as the spindle closes, leaving you unsure of exactly where on the flank you measured. A linear-feed spindle makes contact precisely where you aim.

Measuring force must remain consistent. Point contact concentrates the entire load onto a tiny surface area, resulting in high contact pressure even under moderate force. Too much force causes local flank deformation or flexes the tooth; too little measures dirt and oil film instead. The ratchet stop delivers the exact same force every time, making your measurements reliable and repeatable.

The absolute encoder fits this workflow. In practice, the instrument is typically preset against a nominal master, and losing your zero point during a battery change means having to recalibrate from scratch. With an absolute encoder, your zero setting is preserved.

Three typical applications

  • Gear manufacturing: quality control during and after milling, and post-hardening when dimensions may have shifted.
  • Maintenance: wear monitoring on gears in service, where comparing against baseline data is critical.
  • Incoming inspection: verifying sourced gears against technical drawings before final assembly.

Why it pays off

A misaligned or worn gear drive is heard before it is seen, and by the time damage becomes visible, it has usually spread to bearings, shafts, and the lubrication system. The actual costs end up far beyond the gear itself, and by the time the failure is diagnosed, operational wear has often erased all evidence of the initial defect.

Measuring with reference to the flank instead of the tip provides comparable, reliable data over time: the same tooth, the same point, the same force. It is that trend — rather than a single isolated reading — that reveals wear before critical failure occurs.