Published July 2, 2020 at 07:25
To measure pH, you need a pH indicator or, even better, a pH meter. What is a pH value and why do we measure pH? The pH value is a measure of the acidity of a solution. Acidity is in turn determined by the hydrogen ion concentration. pH is expressed on a so-called logarithmic scale, meaning the difference between, for example, pH 3 and pH 4 is that the hydrogen ion concentration is 10 times higher at pH 3.
Some examples of pH values:
- Battery acid ~ pH 0
- Stomach acid ~ pH 1
- Orange juice ~ pH 4
- Distilled water ~ pH 7
- Washing soda ~ pH 13
The pH value is also affected by the temperature of the solution. You should always use a pH meter with built-in temperature compensation. All of this combined makes pH measurements significantly more complicated than, for example, temperature measurements.
Because pH sensors have low repeatability—meaning that for a given pH concentration they will display different values over time—a pH measurement MUST ALWAYS be preceded by calibration. This is done by first soaking the pH sensor for a number of hours, preferably in standard tap water, before calibrating. A distinction is made between 1-, 2-, and 3-point calibrations. We do not recommend 1-point calibrations, as the linearity (read: accuracy) will be inadequate.
Calibrating a pH meter is done as follows: prepare reference buffer solutions, pH 4.00, pH 7.00, and pH 10.00. You should also have a beaker of distilled (deionized) water to rinse the pH sensor with before moving to the next buffer solution. Pour a few cl of each buffer into 3 separate glasses. Then follow the instructions on the pH meter’s display and immerse the pH sensor into each solution in sequence. Check that the calibration is accepted—it should say ”OK” on the display after each step.