Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The Fuse Trips Once a Night: How to Find the Cause with a Logged Load CurveA core temperature reading in 0.4 seconds makes self-inspection a habit instead of an interruptionWhy Bore Measurements Show Different Values Depending on Who Holds the InstrumentThree Seconds at the Core: How to Make Temperature Control in Food Production Both Faster and SaferThe Brix value decides: get a reading in seconds instead of a guess by eyeThree seconds is enough to tell whether the core temperature holdsTwo-point measurement in an oval hole gives the wrong diameter, three measuring points do notHow to tell in three seconds whether a hole meets the H7 toleranceThe Hole Measures Right in One Direction but Is Still Wrong: Why You Need Three Measuring PointsWhy the Multimeter Shows the Wrong Voltage on a Variable Frequency Drive and How True RMS Fixes ItVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The Fuse Trips Once a Night: How to Find the Cause with a Logged Load CurveA core temperature reading in 0.4 seconds makes self-inspection a habit instead of an interruptionWhy Bore Measurements Show Different Values Depending on Who Holds the InstrumentThree Seconds at the Core: How to Make Temperature Control in Food Production Both Faster and SaferThe Brix value decides: get a reading in seconds instead of a guess by eyeThree seconds is enough to tell whether the core temperature holdsTwo-point measurement in an oval hole gives the wrong diameter, three measuring points do notHow to tell in three seconds whether a hole meets the H7 toleranceThe Hole Measures Right in One Direction but Is Still Wrong: Why You Need Three Measuring PointsWhy the Multimeter Shows the Wrong Voltage on a Variable Frequency Drive and How True RMS Fixes It
Item number 64-854092

Bluetooth Adapter – 1961-13

1.491 SEK

In stock

Practical Bluetooth adapter that enables wireless connectivity between your devices. Perfect for streaming music, connecting accessories, or creating a wireless link between various digital products. Easy installation and use for a more flexible and organized tech environment without cumbersome cables.

Request a quote 64-854092

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

  • Free shipping over 3000 kr excl. VAT
  • Thermometers and measuring instruments for work and home
  • Call us +46 8 753 00 04

Category:

Description

Bluetooth interface adapter type 1961-13 (only K and L series) is a Kræplin precision instrument from the STANDARD LINE series — used for workshop measurement, inspection, and reference work in machine and manufacturer environments. Hardened and ground reference surfaces ensure repeatable measurement; the instrument is designed for handheld or fixture-mounted use depending on the workshop application.

STANDARD LINE build quality. Hardened and ground reference surfaces and contact points for repeatable measurement; matched to Kræplin precision quality class. The instrument integrates with standard inspection workflows in metrology labs and machine shop QC stations.

Usage: position the instrument against the workpiece’s reference surface or feature, and perform the measurement according to the instrument’s standard procedure (depending on type — direct reading, comparative deviation, go/no-go verification, or wrung-stack reference). Zero-verify against the setting standard during periodic verification. Document with a calibration certificate. The instrument’s design supports both one-off inspection and back-to-back QC workflows; its hardened reference surfaces withstand wear from regular workshop use over years of service.

Common applications: workshop incoming inspection of components, on-machine setup checks, fitter and toolmaker bench measurement, calibration lab reference work, and QC workflows within the Kræplin product line where this instrument’s specific role is applicable. The INTERNAL MEASURING INSTRUMENTS category is the standard workshop tool for measurement/reference tasks.

Features

  • Bluetooth interface adapter type 1961-13 (only K and L series)
  • Hardened, ground reference surfaces for repeatable measurement
  • Kræplin build quality
  • Suitable for workshop QC, calibration lab, and bench measurement applications
  • STANDARD LINE series

Specifications

Manufacturer Kræplin
Series STANDARD LINE
Type Kræplin accessories
Article number 64-854092

Compatible accessories

Compatible accessories: Kræplin setting standards and reference standards for periodic verification of accuracy at known dimensions; calibration certificates (ISO 17025) at first delivery and periodic verification — typically a 12-month interval for production floors, 6 months for high-volume lines; Kræplin protective cases and bench storage; Kræplin spare parts and consumables where applicable.

Additional information
Weight 0,153 kg