Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%When the naked eye isn’t enough: measure and document the defect directly in the image instead of guessingMoisture is rarely where you can see it: how to tell whether wood, plasterboard and concrete are dry enoughThe cold room was too warm last night, but nobody knew when it startedThe Fuse Trips Once a Night: How to Find the Cause with a Logged Load CurveA core temperature reading in 0.4 seconds makes self-inspection a habit instead of an interruptionWhy Bore Measurements Show Different Values Depending on Who Holds the InstrumentThree Seconds at the Core: How to Make Temperature Control in Food Production Both Faster and SaferThe Brix value decides: get a reading in seconds instead of a guess by eyeThree seconds is enough to tell whether the core temperature holdsTwo-point measurement in an oval hole gives the wrong diameter, three measuring points do notVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%When the naked eye isn’t enough: measure and document the defect directly in the image instead of guessingMoisture is rarely where you can see it: how to tell whether wood, plasterboard and concrete are dry enoughThe cold room was too warm last night, but nobody knew when it startedThe Fuse Trips Once a Night: How to Find the Cause with a Logged Load CurveA core temperature reading in 0.4 seconds makes self-inspection a habit instead of an interruptionWhy Bore Measurements Show Different Values Depending on Who Holds the InstrumentThree Seconds at the Core: How to Make Temperature Control in Food Production Both Faster and SaferThe Brix value decides: get a reading in seconds instead of a guess by eyeThree seconds is enough to tell whether the core temperature holdsTwo-point measurement in an oval hole gives the wrong diameter, three measuring points do not
Item number 78-1002659-001

Checklite AT100 100 determinations

6.372 SEK

In stock
  • Highly sensitive microbial biomass analysis based on the ATP measurement method
  • No centrifugation required
  • Reduces time and effort for aseptic testing of milk, sour drinks, etc.
  • Easy to use
Request a quote 78-1002659-001

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

  • Free shipping over 3000 kr excl. VAT
  • Thermometers and measuring instruments for work and home
  • Call us +46 8 753 00 04

Category:

Description

78-1002659-001 Test hygiene > Checklite

The CheckLite AT100 is a microbial biomass analysis kit based on the ATP measurement method. It is particularly suitable for aseptic testing of acidic beverages and retort food after appropriate incubation. It contains thermostable firefly luciferase and an ATP-eliminating reagent.
Luciferase reacts specifically with ATP, producing a directly proportional amount of bioluminescence. ATP levels due to extracellular ATP from emulsified products, such as milk, cream, and products containing milk, can be several orders of magnitude higher than the ATP levels found in other food products. This high level of ATP interferes with the sensitive detection of intracellular ATP from contaminating microorganisms. With CheckLite AT100, somatic cells and micelle structures are broken down, and the released ATP and any extracellular ATP are degraded to very low concentrations compared to other ATP methods, enabling sensitive detection of bacteria in emulsified product samples.

1 x 100 analyses


Kit composition
Luciferin-luciferase reagent HS – 2 bottles dark green marked
Reconstitution buffer for Luciferin-luciferase reagent – 5.5 ml x 2 vials pale pink marked
ATP reagent – 5.5 ml x 2 plastic bottles light blue marked
ATP-ELIMINATING REAGENT – 2 vials red pink marked
Reconstitution buffer for ATP-eliminating reagent – 5.5 ml x 2 vials yellow marked
Sample dilution buffer – 25 ml x 4 plastic bottles dark blue marked
Sample treatment reagent – 5.5 ml x 2 plastic bottles brown marked


The concentration of ATP in living cells changes rapidly. Therefore, extract ATP from cells or freeze the cells immediately after sampling. Even during extraction, it may be necessary to inhibit or destroy ATP-degrading enzymes to prevent the enzymes from reducing the ATP concentration.
Prepare the bioluminescence and ATP-eliminating reagents according to the manual. After preparation of the samples, mix the reagent and samples to start the reaction.
By measuring the bioluminescence in a luminometer, such as the recommended C-110, the level of ATP can be determined. These results can be quantified by plotting against a prepared standard curve. The number of microbial cells (colony-forming units, CFU) can be obtained based on the correlation between the amount of ATP and the number of CFU counted in advance using the traditional colony counting method.
For more information, see the manual.