Hoppa till innehåll
Free shipping over 3000 kr excl. VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%A core temperature reading in 0.4 seconds makes self-inspection a habit instead of an interruptionWhy Bore Measurements Show Different Values Depending on Who Holds the InstrumentThree Seconds at the Core: How to Make Temperature Control in Food Production Both Faster and SaferThe Brix value decides: get a reading in seconds instead of a guess by eyeThree seconds is enough to tell whether the core temperature holdsTwo-point measurement in an oval hole gives the wrong diameter, three measuring points do notHow to tell in three seconds whether a hole meets the H7 toleranceThe Hole Measures Right in One Direction but Is Still Wrong: Why You Need Three Measuring PointsWhy the Multimeter Shows the Wrong Voltage on a Variable Frequency Drive and How True RMS Fixes ItMotion blur hides the defect: how strobe lighting freezes a fast-moving detail in the microscope imageVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%A core temperature reading in 0.4 seconds makes self-inspection a habit instead of an interruptionWhy Bore Measurements Show Different Values Depending on Who Holds the InstrumentThree Seconds at the Core: How to Make Temperature Control in Food Production Both Faster and SaferThe Brix value decides: get a reading in seconds instead of a guess by eyeThree seconds is enough to tell whether the core temperature holdsTwo-point measurement in an oval hole gives the wrong diameter, three measuring points do notHow to tell in three seconds whether a hole meets the H7 toleranceThe Hole Measures Right in One Direction but Is Still Wrong: Why You Need Three Measuring PointsWhy the Multimeter Shows the Wrong Voltage on a Variable Frequency Drive and How True RMS Fixes ItMotion blur hides the defect: how strobe lighting freezes a fast-moving detail in the microscope image

The angle can be built from a length or read from a scale, and this is the second approach

Published August 28, 2026 at 05:40

There are two ways to set an angle in a workshop. One is to build it from a length: a sine setup where a stack of gauge blocks under one end determines the angle through pure trigonometry. The method is extremely accurate, and it requires calculations and a stack of blocks.

The other way is to read it. Loosen, swing to the right line, tighten. This V-block has the angle marked directly on it, with a vernier scale that divides the degrees into tenths of an arcminute.

Staellbart v-block med vinkelskala och nonius, kapacitet 6-40 mm

What it is

An adjustable V-block with an angle scale.

  • Dimensions 102 x 30 x 48 mm, capacity Ø6-40 mm
  • Angle range 0 to +60° and 0 to -15°
  • Accuracy 15 arcminutes, vernier 10 arcminutes
  • Hardened and ground reference surfaces
  • Hex key included

Fifteen arcminutes — and why it is enough

A quarter of a degree is coarse compared to a sine setup. And it should be. The two methods are not competing for the same work: the sine plate belongs where the angle is the dimension and must hold within a few arcseconds, while an adjustable V-block belongs where the angle is a setup.

If a cross-hole needs to be drilled in a shaft at forty-five degrees, a chamfer ground, or a round part tilted to make a surface accessible to a dial indicator — then a quarter of a degree is more than sufficient, and the time saved by not having to calculate and stack blocks is the real gain.

Choosing the coarser method deliberately is the difference between being efficient and being sloppy. The mistake is not using an adjustable block, but using it when the drawing calls for arcseconds.

The V-shape provides automatic centering

A prism holds a cylinder against two lines. This means the part centers itself: whether the diameter is six or forty millimeters, the axis ends up in the same plane, right over the block’s line of symmetry.

That is why a V-block is a fixture and not just a holder. If you switch to a part with a different diameter, nothing needs readjusting — the position is dictated by the geometry, not by someone aligning it by eye.

The asymmetric angle range reveals its purpose

0 to +60 degrees in one direction, but only 0 to -15 in the other. This is not a manufacturing coincidence, but a description of how the block is used: the workpiece is normally tilted up, through a wide range, and only slightly in the other direction to allow for corrections or to reach just below zero.

Anyone needing large angles in both directions should look elsewhere — and anyone reading the specification sees this right away, instead of discovering it with the part already clamped.

Three typical use cases

  • Drilling and milling: cross-holes and surfaces at an angle to a shaft’s centerline.
  • Grinding: chamfers and angled surfaces on cylindrical parts.
  • Inspection: tilting a workpiece so that the surface to be measured becomes horizontal.

Why it pays off

The most common reason an angle turns out wrong is not that the instrument was too coarse, but that the setup was improvised — a wedge, a piece of sheet metal, an eyeball estimate. A block with a scale turns the setting into a number that can be written down, repeated next time, and verified by someone else.

And when the same part needs to be made again in six months, the difference between ”roughly like last time” and ”thirty-two degrees twenty” is precisely what determines whether the second batch matches the first.

Read more about the adjustable V-block →

More news

All news