Hoppa till innehåll
Free shipping over 3000 kr excl. VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The hole is right on the drawing but wrong in reality: how to read the deviation directly on the dialThe Right Direction of Rotation Before the Motor Starts: How to Check Phase Sequence in SecondsHow to get ±0.2 °C in both freezer and oven with a thermometer for type T probesHow to find 0.02 mm of runout in a bore where a standard dial indicator will never fitLegionella Control That No Longer Ends Up in a Binder of Handwritten TemperaturesThe cutting fluid always looks the same, but the concentration in the tank doesn’tMeasuring from an image is only reliable when the magnification travels with the imageThe freezer lost temperature overnight – with an alert on your phone, you’ll know before the samples are ruinedWith a Steerable Camera Head, You See the Fault Before You Take the Machine ApartA Bore That Is Right at the Opening Can Be Wrong 400 mm Further InVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The hole is right on the drawing but wrong in reality: how to read the deviation directly on the dialThe Right Direction of Rotation Before the Motor Starts: How to Check Phase Sequence in SecondsHow to get ±0.2 °C in both freezer and oven with a thermometer for type T probesHow to find 0.02 mm of runout in a bore where a standard dial indicator will never fitLegionella Control That No Longer Ends Up in a Binder of Handwritten TemperaturesThe cutting fluid always looks the same, but the concentration in the tank doesn’tMeasuring from an image is only reliable when the magnification travels with the imageThe freezer lost temperature overnight – with an alert on your phone, you’ll know before the samples are ruinedWith a Steerable Camera Head, You See the Fault Before You Take the Machine ApartA Bore That Is Right at the Opening Can Be Wrong 400 mm Further In
Item number 78-1061342

Histamine test strips, 40 pcs / pack, 38221900, Japan

3.307 SEK

In stock
  • Color change indicating histamine content
  • Simple & easy test
  • No instrumentation required
  • Fast results
  • No special training required
Request a quote 78-1061342

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

  • Free shipping over 3000 kr excl. VAT
  • Thermometers and measuring instruments for work and home
  • Call us +46 8 753 00 04

Category:

Description

78-1061342 Test allergens > Test strips for histamine

The Histamine Control Strip should be used to analyze histamine present in food samples using a colorimetric reaction. Analysis results can be verified by changes in reagent color. Comparing color changes with the color chart provides a rough understanding of the histamine content.
The analysis method for this product contains enzymes that act specifically on histamine. In the presence of tetrazolium salt and electron acceptors, histamine dehydrogenase acts on the tetrazolium salt to produce formazan dye (purple). Since the concentration of formazan dye varies depending on the histamine concentration, a rough understanding of the histamine concentration in the sample can be obtained by comparing it with the color chart.
This product simplifies the process of identifying histamine concentration in analysis samples, but it is not intended for exact quantification of histamine or as an official analysis method.

1 x box, 40 analyses (20 x 2 aluminum bags)


Measurement time: 5 min

Storage: 2-8 ℃ (Do not freeze)

Quantitative range: 20–80 ppm (for fish sauce: 5-fold diluted fish sauce becomes 100-400 ppm)

Detection method: Visual reading of colorimetric reaction


Remove the product from the refrigerator and allow it to reach room temperature (18 – 30℃). Once the product has reached room temperature, it should be used as soon as possible.

Dilute an analysis sample two to five times. Solid analysis samples should be ground. False positive results can be prevented by heating the diluted sample. 

Pull the strip out of the main body.

Immerse the strip in the diluted sample. If the analysis sample is in solid form, ensure no solid particles stick to the strip. 

Return the strip to the main body and push it fully into the main body.

Hold the main body and shake it. The remaining colorimetric reagent will dissolve completely. 

After five minutes, check the color of the reaction solution. A rough understanding of the histamine concentration can be obtained by comparing the color with the color chart.

Reviews (0)

There are no reviews yet.

Be the first to review

Your e-mail address is not published.

Your rating *