Hoppa till innehåll
Free shipping over 5.552 SEK ex VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%How to get ±0.2 °C in both freezer and oven with a thermometer for type T probesHow to find 0.02 mm of runout in a bore where a standard dial indicator will never fitLegionella Control That No Longer Ends Up in a Binder of Handwritten TemperaturesThe cutting fluid always looks the same, but the concentration in the tank doesn’tMeasuring from an image is only reliable when the magnification travels with the imageThe freezer lost temperature overnight – with an alert on your phone, you’ll know before the samples are ruinedWith a Steerable Camera Head, You See the Fault Before You Take the Machine ApartA Bore That Is Right at the Opening Can Be Wrong 400 mm Further InWhen the naked eye isn’t enough: measure and document the defect directly in the image instead of guessingMoisture is rarely where you can see it: how to tell whether wood, plasterboard and concrete are dry enoughVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%How to get ±0.2 °C in both freezer and oven with a thermometer for type T probesHow to find 0.02 mm of runout in a bore where a standard dial indicator will never fitLegionella Control That No Longer Ends Up in a Binder of Handwritten TemperaturesThe cutting fluid always looks the same, but the concentration in the tank doesn’tMeasuring from an image is only reliable when the magnification travels with the imageThe freezer lost temperature overnight – with an alert on your phone, you’ll know before the samples are ruinedWith a Steerable Camera Head, You See the Fault Before You Take the Machine ApartA Bore That Is Right at the Opening Can Be Wrong 400 mm Further InWhen the naked eye isn’t enough: measure and document the defect directly in the image instead of guessingMoisture is rarely where you can see it: how to tell whether wood, plasterboard and concrete are dry enough
Item number 76-1502990-1400

Compact Dry XSA – for Staphylococcus Aureus – 1400 test plates per pack, 38210000, Japan

17.940 SEK

In stock
  • Clear and easy-to-use portable plate: No medium preparation is required, eliminating medium waste and the need for sterilization equipment to prepare the medium.
  • Detection of colonies on the plate is simple and clear.
  • Individual colonies on the plate can be isolated for further identification tests
Request a quote 76-1502990-1400

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

  • Free shipping over 3000 kr excl. VAT
  • Thermometers and measuring instruments for work and home
  • Call us +46 8 753 00 04

Category:

Description

Compact Dry X-SA is a simple and safe test method for detecting and quantifying Staphylococcus aureus. These are spherical bacteria that are typically arranged in clusters under the microscope. Their potential pathogenicity stems from their ability to produce enterotoxins (SET), which accumulate in food when contaminated and cannot be completely inactivated even by heat treatment. Food contamination with S. aureus almost always originates from humans (hands, sneezing, coughing). S. aureus is therefore also considered an indicator of inadequate personal hygiene


Incubation time and temperature: 24 ± 2 hours at 35 ± 2 °C, AOAC recommendation 35 ± 2 °C, NordVal /MicroVal recommendation 37 ± 1 °C
Shelf life: Room temperature (+ 1 to + 30 °C)
Storage: 21 months after manufacture


Sample preparation Viable count

in water or liquid food
Drop 1 ml of sample (dilute if necessary) onto the center of the Compact Dry plate.

Viable count in solid food
Add buffer solution to the sample and homogenize with a stomacher®. Drop 1 ml of sample (dilute if necessary) onto the center of the dry pad on the Compact Dry plate.

Viable count in swab test samples
Use the cotton swab to wipe the surface, insert it into the unit with the elution solution. Drop 1 ml of elution solution (dilute if necessary) onto the center of the Compact Dry plate. It is recommended to use Swab for Compact Dry offered by HyServe Id no. 1 002 952/3 (40/240 pieces).

Test instructions

Open the lid and drop 1 ml of sample onto the center of the Compact Dry plate.
The sample automatically and evenly diffuses into the pad, converting the dry pad into a gel within seconds.
Replace the lid on the plate and write the necessary information in the memo section.
Invert the covered plate and place it in the incubator.
After incubation, count the number of light blue/blue colonies. White paper placed under the plate helps in counting the colonies.