Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%How to Measure Surface Temperature from a Safe Distance Without Losing TraceabilityThe core temperature of a delivery shows whether the cold chain held, and only a probe thermometer can reveal itThe Surface Temperature of a Delivery Can Be Checked in Three Seconds Without Touching the FoodThe hole is right on the drawing but wrong in reality: how to read the deviation directly on the dialThe Right Direction of Rotation Before the Motor Starts: How to Check Phase Sequence in SecondsHow to get ±0.2 °C in both freezer and oven with a thermometer for type T probesHow to find 0.02 mm of runout in a bore where a standard dial indicator will never fitLegionella Control That No Longer Ends Up in a Binder of Handwritten TemperaturesThe cutting fluid always looks the same, but the concentration in the tank doesn’tMeasuring from an image is only reliable when the magnification travels with the imageVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%How to Measure Surface Temperature from a Safe Distance Without Losing TraceabilityThe core temperature of a delivery shows whether the cold chain held, and only a probe thermometer can reveal itThe Surface Temperature of a Delivery Can Be Checked in Three Seconds Without Touching the FoodThe hole is right on the drawing but wrong in reality: how to read the deviation directly on the dialThe Right Direction of Rotation Before the Motor Starts: How to Check Phase Sequence in SecondsHow to get ±0.2 °C in both freezer and oven with a thermometer for type T probesHow to find 0.02 mm of runout in a bore where a standard dial indicator will never fitLegionella Control That No Longer Ends Up in a Binder of Handwritten TemperaturesThe cutting fluid always looks the same, but the concentration in the tank doesn’tMeasuring from an image is only reliable when the magnification travels with the image
Item number 76-1502889-1400

Compact Dry ETB – for enterobacteria – 1400 test plates per pack, 38210000, Japan

18.068 SEK

In stock
  • Clear and easy-to-use portable plate: No medium preparation is required, eliminating waste of medium and the need for sterilization equipment to prepare the medium.
  • Detection of colonies on the plate is simple and clear.
  • Individual colonies on the plate can be isolated for further identification tests.
Request a quote 76-1502889-1400

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

  • Free shipping over 3000 kr excl. VAT
  • Thermometers and measuring instruments for work and home
  • Call us +46 8 753 00 04

Category:

Description

ETB refers to Enterobacteria, which are Gram-negative, rod-shaped bacteria. Compact Dry ETB is a ready-to-use, chromogenic Compact Dry plate suitable for both process and finished product control. With Compact Dry ETB, it is very easy to detect Enterobacteriaceae. Its substrate allows for easy differentiation of Enterobacteria from other groups.


Incubation time and temperature: 24 ± 2 hours at 37 ± 1 °C
Shelf life: Room temperature (+ 1 to + 30 °C)
Storage: 16 months after manufacture.


Sample preparation
Viable count in water or liquid food
Drop 1 ml of sample (dilute if necessary) onto the center of the Compact Dry plate.
Viable count in solid food
Add buffer solution (e.g., 0.9% saline, PBS, buffered peptone water, etc.) to the sample and homogenize with a stomacher®. Drop 1 ml of sample (dilute if necessary) onto the center of the dry pad on the Compact Dry plate.
Viable count in swab test samples
Use a sterile wet wipe to wipe the surface to be analyzed and return it to the unit with the elution solution.
After shaking the unit (approx. 10 seconds), drop 1 ml of elution solution (dilute if necessary) onto the center of the Compact Dry plate.
Use Compact Dry Swab (art. No. ZCS1002953, content 40 pcs) as a single-use applicator (1 ml) or Promedia ST-25 (art. No. Z0302, content 10 pcs) as a multiple applicator (10 ml) for this procedure.

Test instructions

Open the top lid of the Compact Dry plate. Drop 1 ml of sample in the center of the plate.
The sample automatically and evenly diffuses into the pad, converting the dry pad into a gel within seconds.
Close the lid on the plate and place it in the incubator in a horizontal position.
After incubation, count the number of all grown colonies on the plate.