Hoppa till innehåll
Free shipping over 3000 kr excl. VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The core temperature of a delivery shows whether the cold chain held, and only a probe thermometer can reveal itThe Surface Temperature of a Delivery Can Be Checked in Three Seconds Without Touching the FoodThe hole is right on the drawing but wrong in reality: how to read the deviation directly on the dialThe Right Direction of Rotation Before the Motor Starts: How to Check Phase Sequence in SecondsHow to get ±0.2 °C in both freezer and oven with a thermometer for type T probesHow to find 0.02 mm of runout in a bore where a standard dial indicator will never fitLegionella Control That No Longer Ends Up in a Binder of Handwritten TemperaturesThe cutting fluid always looks the same, but the concentration in the tank doesn’tMeasuring from an image is only reliable when the magnification travels with the imageThe freezer lost temperature overnight – with an alert on your phone, you’ll know before the samples are ruinedVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The core temperature of a delivery shows whether the cold chain held, and only a probe thermometer can reveal itThe Surface Temperature of a Delivery Can Be Checked in Three Seconds Without Touching the FoodThe hole is right on the drawing but wrong in reality: how to read the deviation directly on the dialThe Right Direction of Rotation Before the Motor Starts: How to Check Phase Sequence in SecondsHow to get ±0.2 °C in both freezer and oven with a thermometer for type T probesHow to find 0.02 mm of runout in a bore where a standard dial indicator will never fitLegionella Control That No Longer Ends Up in a Binder of Handwritten TemperaturesThe cutting fluid always looks the same, but the concentration in the tank doesn’tMeasuring from an image is only reliable when the magnification travels with the imageThe freezer lost temperature overnight – with an alert on your phone, you’ll know before the samples are ruined
Item number 76-1000888

Dilution Stand for Compact Dry – PBS, 128 containers per box, each 9 ml, 38221900, Japan

1.264 SEK

In stock
  • Simple preparation of a dilution series
  • Distributed diluent
  • Time- and cost-effective
  • Storage at room temperature
Request a quote 76-1000888

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

  • Free shipping over 3000 kr excl. VAT
  • Thermometers and measuring instruments for work and home
  • Call us +46 8 753 00 04

Category:

Description

The PBS Dilution Rack for Compact Dry helps you dilute samples efficiently and quickly, without time-consuming additional preparations. It is supplied sterile and ready to use.

The PBS Dilution Rack contains phosphate-buffered saline as the diluent.

By adding 1 ml of sample to the first well, mixing, and transferring 1 ml from that well to the next, a 1:10 dilution series is prepared very easily.

128 wells in 32 racks with 4 separable wells each (9 ml each)


Volume 9 ml/well

Store at room temperature

Shelf life 2 years from date of manufacture


Poke two holes in the foil on each of the wells.

After preparation of the homogenized sample, dispense 1 ml of the sample with a sterile pipette into the well through one of the holes. (for a ten-fold dilution, 10-1)

Mix by pipetting up and down.

Using a new pipette, enter through the second punched hole, draw up 1 ml, and transfer to a Compact Dry plate (see below).

To generate further dilutions, transfer 1 ml of sample to the next well (dilution 10-2) and so on. Repeat this step until you reach the calculated dilution.

Specification

The PBS Dilution Rack for Compact Dry helps you dilute samples efficiently and quickly, without time-consuming additional preparations. It is supplied sterile and ready to use.

The PBS Dilution Rack contains phosphate-buffered saline as the diluent.

By adding 1 ml of sample to the first well, mixing, and transferring 1 ml from that well to the next, a 1:10 dilution series is prepared very easily.

128 wells in 32 racks with 4 separable wells each (9 ml each)


Volume 9 ml/well

Store at room temperature

Shelf life 2 years from date of manufacture


Poke two holes in the foil on each of the wells.

After preparation of the homogenized sample, dispense 1 ml of the sample with a sterile pipette into the well through one of the holes. (for a ten-fold dilution, 10-1)

Mix by pipetting up and down.

Using a new pipette, enter through the second punched hole, draw up 1 ml, and transfer to a Compact Dry plate (see below).

To generate further dilutions, transfer 1 ml of sample to the next well (dilution 10-2) and so on. Repeat this step until you reach the calculated dilution.